Previous | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | Next | ...
123 |BM TECHNOLOGIES |
CW54 for liquids and solids
Applications:
Storage tanks with hazardous working conditions.
Range: until70 m
Accuracy: 20 mm
Process connection: flanges SS 316L PN16
DN150, 200
Antenna: conical Ø 150, 200, 200(Lengthen) mm
Materials: antenna: SS 316L
housing: plastic PBT-FR / Aluminium/ AISI
flanges: AISI 316L
Working temperature: -40…200°C
Storage temperature: -40 ÷ 80°C
Relative umidity: <95%
Pressure: -1 ÷ 40 bar
Resistance to vibrations: mechanical vibrations 10m/s2, 10÷150Hz
Frequency: 6 GHz
Angle emission lobe: 24°
Interval of measure: ~1sec
Interval of updating: ~1sec
Resolution display: 1mm
Supply 2 wires version:
- Input voltage: 15÷36Vdc
- Absorption: max. 22.5mA
- Ripple allowed: <100Hz, Uss>1V;
100Hz÷100KHz, Uss<10mV
Supply 4 wires version:
- Standard input version voltage: 24Vdc ±10%; 230Vac ±10%
- Absorption: max. 4VA, 2W
Output signal: 2/4 wires 4-20 mA, HART
Resolution: 1,6μA
Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA
Time of integration: 0÷99s, programmable
Cables entry: 1x PG 13.5
Weight until ~10 kg (depending by flange Ø)
|
CW54 BM SERIES WAVE COMPACT 6.3 GHZ- For Liquids & Solids
|
Pulse Radar|Process Controls |
|
122 |BM TECHNOLOGIES |
CW53 for liquids and solids
Applications:
Storage tanks with hazardous working conditions.
Range: until30 m
Accuracy: 10 mm
Process connection: flanges AISI 316L SS PN16
DN50,80,100,150,200
Antenna: conicalsØ 50, 80, 100, 150, 200
Materials: antenna: SS 316L / PTFE
housing: plastic PBT-FR / Aluminium/ AISI
flanges: SS 316L
Working temperature: -40…200°C
Storage temperature: -40 ÷ 80°C
Relative umidity: <95%
Pressure: -1 ÷ 40 bar
Resistance to vibrations: mechanical vibrations 10m/s2, 10÷150Hz
Frequency: 6 GHz
Angle emission lobe: 29°; 26°; 24°; 20° (depending by cones Ø)
Interval of measure: ~1sec
Interval of updating: ~1sec
Resolution display: 1mm
Supply 2 wires version:
- Input voltage: 15÷36Vdc
- Absorption: max. 22.5mA
- Ripple allowed: <100Hz, Uss>1V;
100Hz÷100KHz, Uss<10mV
Supply 4 wires version:
- Standard input version voltage: 24Vdc ±10%; 230Vac ±10%
- Absorption: max. 4VA, 2W
Output signal: 2/4 wires 4-20 mA, HART
Resolution: 1,6μA
Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA
Time of integration: 0÷99s, programmable
Cables entry: 1x PG 13.5
Weight until ~6 kg (depending by flange Ø)
|
CW53 BM SERIES WAVE COMPACT 6.3 GHZ- For Liquids & Solids
|
Pulse Radar|Process Controls |
|
121 |BM TECHNOLOGIES |
CW52 for liquids
Applications: Level measurement, suitable for highly corrosive media in defined
conditions of temperature or pressure.
Range: until 30 m
Accuracy: 10 mm
Process connection: Protected flanges SS 316L PN16
DN 50, 100, 150, 200, 250, 300 PTFE
Antenna: Rod
Materials: antenna: PTFE
housing: plastic PBT-FR / Aluminium / AISI
flanges: SS 316L
Working temperature: -40 ÷150°C
Storage temperature: -40 ÷ 80°C
Relative umidity: <95%
Pressure of utilization: -1 ÷ 16 bar
Resistance to vibrations: mechanical vibrations10m/s2, 10÷150Hz
Frequency: 6 GHz
Angle emission lobe: 24°
Interval of measure: ~1sec
Interval of updating: ~1sec
Resolution display: 1mm
Supply 2 wires version:
- Input voltages: 15÷36Vdc
- Absorption: 22.5mA
- Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV
Supply 4 wires version:
- Standard input voltages: 24Vdc ±10%; 230Vac ±10%
- Absorption: max. 4VA, 2W
Output signal: 2/4 wires 4-20 mA, HART
Resolution: 1,6μA
Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA
Integration time: 0÷99s, programmable
Cables entry: 1x PG 13.5
Weight: until ~5 kg (depending by flange Ø)
|
CW52 BM SERIES WAVE COMPACT 6.3 GHZ- For Liquids
|
Pulse Radar|Process Controls |
|
120 |BM TECHNOLOGIES |
CW51 for liquids
Applications:
Level measurement, Suitable for highly corrosive media.
Range: until 30 m
Accuracy: ± 10 mm
Process connection: G1½ “A - NPT
Antenna: Rod
Materials: antenna: PP / PTFE
housing: plastic PBT-FR / Aluminium / Stainless Steel 316L
flanges: AISI 316L
Working temperature: -40 ÷120°C
Storage temperature: -40 ÷ 80°C
Relative umidity: <95%
Pressure of utilization: -1 ÷ 3 bar
Resistance to vibrations: mechanical vibrations 10m/s2, 10÷150Hz
Frequency: 6 GHz
Angle emission lobe: 24°
Interval of measure: ~1sec
Interval of updating: ~1sec
Resolution display: 1mm
Supply 2 wires version:
- Input voltages: 15÷36Vdc
- Absorption: max. 22.5mA
- Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV
Supply 4 wires version:
- Standard input voltages: 24Vdc ±10%; 230Vac ±10%
- Absorption: max. 4VA, 2W
Output signal: 2/4 wires 4-20 mA, HART
Resolution: 1,6μA
Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA
Integration time: 0÷99s, programmable
Cables entry: 1x PG 13.5
Weight: ~2 kg
|
CW51 BM SERIES WAVE COMPACT 6.3 GHZ- For Liquids
|
Pulse Radar|Process Control |
|
119 |Anthone |
1.Brief Introduction
LU-C2100 blue (LU-C3000 color) series recorders may be 1 to 8 channels program PID control and the program control curve may reach 200 segments.
2. technical parameters
◆ Display windows : 320×240 high resolution chart blue-white LCD
◆ Input accuracy: ± (0.2%F.S+1) digit
◆input type: Standard voltage 0-5V, 1-5V
standard current 0-10mA, 4-20mA
T.C: K, S, B, T, E, J, Wre325, N
RTD: Pt100, Cu50, Cu100
specially input: R, WRe526, mV signal, other
◆output types: Switch output: Relay contact output (resistance 250VAC/0.8A or 250VAC/3A)
linear current output: 0-10mA, 4-20mA, 0-20mA (software free set)
linear voltage output: 0-5V, 1-5V, 0-10V (indicates when ordering)
silicon-controlled zero-crossing trigger
the SSR trigger (12V/50mA)
DC12V/50mA
DC24V/50mA
DC5V/50mA
the transform output: 4-20mA (the load <650Ω)、1-5V
0-10mA(the load <1000Ω)、0-5V
Communication connection: RS232 or RS485
storage medium: U disk/256M, U disk/512M
◆5 to 200 segments of control curves
◆Record date: 8 pens
without U disk, 5.69 days /pen (1 sceond interval) ~3.7 years /pen (4 minutes interval)
U disk/256M, 256×[5.69 days /pen (1 sceond interval) ~3.7 years /pen (4 minutes interval)]
◆Storage time: T=storage capacity/ the sum of the reciprocal of every open channel’s record interval; when storage data is temple, the storage capacity also the total storage is 976×504.
For example: when the storage data is temple, the open channels are 1, 3, 5, 7, the record interval of every channel is 1second, 5seconds, 10 seconds, 20seconds, then
T= 976×504/(1/1+1/5+1/10+1/20)=364373 seconds=101.21 hours=4.22 days
◆cut off protection time: the data can be stored forever when the electricity is cut off for it adopts FLASH MEMORY, it can run accurately when cut off if hard clocks is equipped.
◆Power source: Switch power supply 85VAC-264VAC, 50Hz±1Hz, power consumption 12W
◆Ambient temperature: 0-45 ℃
◆ambient humidity: 0-85%RH
|
LU-C2100 Blue (LU-C3000 Color) LCD program PID Control
|
Paperless Electronic Recorders|Recorder |
|
Previous | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | Next | ...
|
|