| Model | FT3 | | Description | The Fox Model FT3 Thermal Gas Mass Flow Meter and Temperature Transmitter measures two important process variables in one rugged instrument.
The Model FT3 measures gas flow rate in standard units without the need for temperature and pressure compensation.
Calibration Validation, using the CAL-V™ and Zero CAL-CHECK™ features, is an in-situ calibration routine that validates the flow meter's accuracy by testing the functionality of the sensor and it associated signal processing circuitry. | | Maker | Fox | | Category | Thermal Mass Flow | | Highlights | | | Applications | | | Industry | Gas Flow | | Keywords | | | Product Image |  | | Model | FT2A | | Description | The Improved Fox Model FT2A Thermal Gas Mass Flow Meter and Temperature Transmitter measures two important process variables in one rugged instrument.
The Model FT2A continues to accurately measure gas flow rate in standard units without the need for temperature and pressure compensation. Some additional features available on the FT2A include a standard display, a standard USB port to connect to a PC, and the option of BACnet MS/TP communication protocol. | | Maker | Fox | | Category | Thermal Mass Flow | | Highlights | | | Applications | | | Industry | Gas Flow | | Keywords | | | Product Image |  | | Model | CW57 BM SERIES WAVE COMPACT 26 GHZ - for Liquids | | Description | CW57 for liquids Applications: Storage tanks with hazardous working conditions. Range: until20 m Accuracy: 3 mm Process connection: flanges DN50, 80, 100, 150 AISI316L Antenna: conical Ø 40, 48, 75, 95 Materials: antenna: PTFE housing: plastic PBT-FR / Aluminium/ AISI flanges: AISI 316L / PTFE Working temperature: -40…150°C Storage temperature: -40 ÷ 80°C Relative umidity: <95% Pressure: -1 ÷ 16 bar Resistance to vibrations: mechanical vibrations 10m/s2, 10÷150Hz Frequency: 26 GHz Angle emission lobe: Ø50 > 18°; Ø80…150 > 10°; Interval of measure: ~1sec Interval of updating: ~1sec Resolution display: 1mm Supply 2 wires version: - Input voltage: 15÷36Vdc - Absorption: max. 22.5mA - Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV Supply 4 wires version: - Standard input version voltage: 24Vdc ±10%; 230Vac ±10% - Absorption: max. 4VA, 2W Output signal: 2/4 wires 4-20 mA, HART Resolution: 1,6μA Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA Time of integration: 0÷20s, programmable Cables entry: 1x PG 13.5 Weight until ~6 kg (depending by flange Ø) | | Maker | BM TECHNOLOGIES | | Category | Pulse Radar | | Highlights | | | Applications | | | Industry | Process Controls | | Keywords | Process Controls | | Product Image |  | | Model | CW56 BM SERIES WAVE COMPACT 26 GHZ- For Liquids & Solids | | Description | CW56 for liquids and solids Applications: Level measurement, suitable for highly corrosive media in defined conditions of temperature or pressure. Range: until 30 m Accuracy: ± 3 mm Process connection: G1½ “A flanges DN50, 80, 100, 150 AISI 316L Antenna: Cones Ø 48, 78, 98, 98 Lengthen, 123 Materials: antenna: AISI 316L / PTFE / PP housing: plastic PBT-FR / Aluminium / AISI flanges: AISI 316L / PTFE / PP Working temperature: -40 ÷400°C Storage temperature: -40 ÷ 80°C Relative umidity: <95% Pressure of utilization: -1 ÷ 40 bar Resistance to vibrations: mechanical vibrations10m/s2, 10÷150Hz Frequency: 26 GHz Angle emission lobe: Ø 40 >22°; Ø 48 >18°; Ø 75 >10° ; Ø 95 >8° Interval of measure: ~1sec Interval of updating: ~1sec Resolution display: 1mm Supply 2 wires version: - Input voltages: 15÷36Vdc - Absorption: 22.5mA - Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV Supply 4 wires version: - Standard input voltages: 24Vdc ±10%; 230Vac ±10% - Absorption: max. 4VA, 2W Output signal: 2/4 wires 4-20 mA, HART Resolution: 1,6μA Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA Integration time: 0÷20s, programmable Cables entry: 1x PG 13.5 Weight: until ~5 kg (depending by flange Ø) | | Maker | BM TECHNOLOGIES | | Category | Pulse Radar | | Highlights | | | Applications | Liquid and Solid Level | | Industry | Process Controls | | Keywords | | | Product Image |  | | Model | CW55 BM SERIES WAVE COMPACT 26 GHZ- For Liquids | | Description | CW55 for liquids Applications: Level measurement, suitable for highly corrosive media. Range: until 10 m Accuracy: ± 5 mm Process connection: G1½ “A - NPT Antenna: Pole Materials: antenna: PVDF / PTFE housing: plastic PBT-FR / Aluminium / AISI flanges: AISI 316L Working temperature: -40 ÷130°C Storage temperature: -40 ÷ 80°C Relative umidity: <95% Pressure of utilization: -1 ÷ 3 bar Resistance to vibrations: mechanical vibrations10m/s2, 10÷150Hz Frequency: 26 GHz Angle emission lobe: 22° Interval of measure: ~1sec Interval of updating: ~1sec Resolution display: 1mm Supply 2 wires version: - Input voltages: 15÷36Vdc - Absorption: max. 22.5mA - Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV Supply 4 wires version: - Standard input voltages: 24Vdc ±10%; 230Vac ±10% - Absorption: max. 4VA, 2W Output signal: 2/4 wires 4-20 mA, HART Resolution: 1,6μA Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA Integration time: 0÷20s, programmable Cables entry: 1x PG 13.5 Weight: ~2 kg | | Maker | BM TECHNOLOGIES | | Category | Pulse Radar | | Highlights | Process Controls | | Applications | Liquid Level | | Industry | Process Controls | | Keywords | | | Product Image |  | | Model | CW54 BM SERIES WAVE COMPACT 6.3 GHZ- For Liquids & Solids | | Description | CW54 for liquids and solids Applications: Storage tanks with hazardous working conditions. Range: until70 m Accuracy: 20 mm Process connection: flanges SS 316L PN16 DN150, 200 Antenna: conical Ø 150, 200, 200(Lengthen) mm Materials: antenna: SS 316L housing: plastic PBT-FR / Aluminium/ AISI flanges: AISI 316L Working temperature: -40…200°C Storage temperature: -40 ÷ 80°C Relative umidity: <95% Pressure: -1 ÷ 40 bar Resistance to vibrations: mechanical vibrations 10m/s2, 10÷150Hz Frequency: 6 GHz Angle emission lobe: 24° Interval of measure: ~1sec Interval of updating: ~1sec Resolution display: 1mm Supply 2 wires version: - Input voltage: 15÷36Vdc - Absorption: max. 22.5mA - Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV Supply 4 wires version: - Standard input version voltage: 24Vdc ±10%; 230Vac ±10% - Absorption: max. 4VA, 2W Output signal: 2/4 wires 4-20 mA, HART Resolution: 1,6μA Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA Time of integration: 0÷99s, programmable Cables entry: 1x PG 13.5 Weight until ~10 kg (depending by flange Ø) | | Maker | BM TECHNOLOGIES | | Category | Pulse Radar | | Highlights | | | Applications | liquid and solid level | | Industry | Process Controls | | Keywords | Process Controls | | Product Image |  | | Model | CW53 BM SERIES WAVE COMPACT 6.3 GHZ- For Liquids & Solids | | Description | CW53 for liquids and solids Applications: Storage tanks with hazardous working conditions. Range: until30 m Accuracy: 10 mm Process connection: flanges AISI 316L SS PN16 DN50,80,100,150,200 Antenna: conicalsØ 50, 80, 100, 150, 200 Materials: antenna: SS 316L / PTFE housing: plastic PBT-FR / Aluminium/ AISI flanges: SS 316L Working temperature: -40…200°C Storage temperature: -40 ÷ 80°C Relative umidity: <95% Pressure: -1 ÷ 40 bar Resistance to vibrations: mechanical vibrations 10m/s2, 10÷150Hz Frequency: 6 GHz Angle emission lobe: 29°; 26°; 24°; 20° (depending by cones Ø) Interval of measure: ~1sec Interval of updating: ~1sec Resolution display: 1mm Supply 2 wires version: - Input voltage: 15÷36Vdc - Absorption: max. 22.5mA - Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV Supply 4 wires version: - Standard input version voltage: 24Vdc ±10%; 230Vac ±10% - Absorption: max. 4VA, 2W Output signal: 2/4 wires 4-20 mA, HART Resolution: 1,6μA Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA Time of integration: 0÷99s, programmable Cables entry: 1x PG 13.5 Weight until ~6 kg (depending by flange Ø) | | Maker | BM TECHNOLOGIES | | Category | Pulse Radar | | Highlights | Process Controls | | Applications | Liquid Level, solid level | | Industry | Process Controls | | Keywords | Pulse Radar | | Product Image |  | | Model | CW52 BM SERIES WAVE COMPACT 6.3 GHZ- For Liquids | | Description | CW52 for liquids Applications: Level measurement, suitable for highly corrosive media in defined conditions of temperature or pressure. Range: until 30 m Accuracy: 10 mm Process connection: Protected flanges SS 316L PN16 DN 50, 100, 150, 200, 250, 300 PTFE Antenna: Rod Materials: antenna: PTFE housing: plastic PBT-FR / Aluminium / AISI flanges: SS 316L Working temperature: -40 ÷150°C Storage temperature: -40 ÷ 80°C Relative umidity: <95% Pressure of utilization: -1 ÷ 16 bar Resistance to vibrations: mechanical vibrations10m/s2, 10÷150Hz Frequency: 6 GHz Angle emission lobe: 24° Interval of measure: ~1sec Interval of updating: ~1sec Resolution display: 1mm Supply 2 wires version: - Input voltages: 15÷36Vdc - Absorption: 22.5mA - Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV Supply 4 wires version: - Standard input voltages: 24Vdc ±10%; 230Vac ±10% - Absorption: max. 4VA, 2W Output signal: 2/4 wires 4-20 mA, HART Resolution: 1,6μA Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA Integration time: 0÷99s, programmable Cables entry: 1x PG 13.5 Weight: until ~5 kg (depending by flange Ø) | | Maker | BM TECHNOLOGIES | | Category | Pulse Radar | | Highlights | | | Applications | Liquid Level | | Industry | Process Controls | | Keywords | | | Product Image |  | | Model | CW51 BM SERIES WAVE COMPACT 6.3 GHZ- For Liquids | | Description | CW51 for liquids Applications: Level measurement, Suitable for highly corrosive media. Range: until 30 m Accuracy: ± 10 mm Process connection: G1½ “A - NPT Antenna: Rod Materials: antenna: PP / PTFE housing: plastic PBT-FR / Aluminium / Stainless Steel 316L flanges: AISI 316L Working temperature: -40 ÷120°C Storage temperature: -40 ÷ 80°C Relative umidity: <95% Pressure of utilization: -1 ÷ 3 bar Resistance to vibrations: mechanical vibrations 10m/s2, 10÷150Hz Frequency: 6 GHz Angle emission lobe: 24° Interval of measure: ~1sec Interval of updating: ~1sec Resolution display: 1mm Supply 2 wires version: - Input voltages: 15÷36Vdc - Absorption: max. 22.5mA - Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV Supply 4 wires version: - Standard input voltages: 24Vdc ±10%; 230Vac ±10% - Absorption: max. 4VA, 2W Output signal: 2/4 wires 4-20 mA, HART Resolution: 1,6μA Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA Integration time: 0÷99s, programmable Cables entry: 1x PG 13.5 Weight: ~2 kg | | Maker | BM TECHNOLOGIES | | Category | Pulse Radar | | Highlights | | | Applications | Liquid Level | | Industry | Process Control | | Keywords | | | Product Image |  | | Model | LU-C2100 Blue (LU-C3000 Color) LCD program PID Control | | Description | 1.Brief Introduction LU-C2100 blue (LU-C3000 color) series recorders may be 1 to 8 channels program PID control and the program control curve may reach 200 segments. 2. technical parameters ◆ Display windows : 320×240 high resolution chart blue-white LCD ◆ Input accuracy: ± (0.2%F.S+1) digit ◆input type: Standard voltage 0-5V, 1-5V standard current 0-10mA, 4-20mA T.C: K, S, B, T, E, J, Wre325, N RTD: Pt100, Cu50, Cu100 specially input: R, WRe526, mV signal, other ◆output types: Switch output: Relay contact output (resistance 250VAC/0.8A or 250VAC/3A) linear current output: 0-10mA, 4-20mA, 0-20mA (software free set) linear voltage output: 0-5V, 1-5V, 0-10V (indicates when ordering) silicon-controlled zero-crossing trigger the SSR trigger (12V/50mA) DC12V/50mA DC24V/50mA DC5V/50mA the transform output: 4-20mA (the load <650Ω)、1-5V 0-10mA(the load <1000Ω)、0-5V Communication connection: RS232 or RS485 storage medium: U disk/256M, U disk/512M ◆5 to 200 segments of control curves ◆Record date: 8 pens without U disk, 5.69 days /pen (1 sceond interval) ~3.7 years /pen (4 minutes interval) U disk/256M, 256×[5.69 days /pen (1 sceond interval) ~3.7 years /pen (4 minutes interval)] ◆Storage time: T=storage capacity/ the sum of the reciprocal of every open channel’s record interval; when storage data is temple, the storage capacity also the total storage is 976×504. For example: when the storage data is temple, the open channels are 1, 3, 5, 7, the record interval of every channel is 1second, 5seconds, 10 seconds, 20seconds, then T= 976×504/(1/1+1/5+1/10+1/20)=364373 seconds=101.21 hours=4.22 days ◆cut off protection time: the data can be stored forever when the electricity is cut off for it adopts FLASH MEMORY, it can run accurately when cut off if hard clocks is equipped. ◆Power source: Switch power supply 85VAC-264VAC, 50Hz±1Hz, power consumption 12W ◆Ambient temperature: 0-45 ℃ ◆ambient humidity: 0-85%RH | | Maker | Anthone | | Category | Paperless Electronic Recorders | | Highlights | | | Applications | Process Controls | | Industry | Recorder | | Keywords | Automation | | Product Image |  |
|
|