Products Details


ModelFT3
DescriptionThe Fox Model FT3 Thermal Gas Mass Flow Meter and Temperature Transmitter measures two important process variables in one rugged instrument.

The Model FT3 measures gas flow rate in standard units without the need for temperature and pressure compensation.

Calibration Validation, using the CAL-V™ and Zero CAL-CHECK™ features, is an in-situ calibration routine that validates the flow meter's accuracy by testing the functionality of the sensor and it associated signal processing circuitry.
MakerFox
CategoryThermal Mass Flow
Highlights 
Applications 
IndustryGas Flow
Keywords 
Product Image
ModelFT2A
DescriptionThe Improved Fox Model FT2A Thermal Gas Mass Flow Meter and Temperature Transmitter measures two important process variables in one rugged instrument.

The Model FT2A continues to accurately measure gas flow rate in standard units without the need for temperature and pressure compensation. Some additional features available on the FT2A include a standard display, a standard USB port to connect to a PC, and the option of BACnet MS/TP communication protocol.
MakerFox
CategoryThermal Mass Flow
Highlights 
Applications 
IndustryGas Flow
Keywords 
Product Image
ModelCW57 BM SERIES WAVE COMPACT 26 GHZ - for Liquids
DescriptionCW57 for liquids

Applications:

Storage tanks with hazardous working conditions.

Range: until20 m

Accuracy: 3 mm

Process connection: flanges DN50, 80, 100, 150 AISI316L

Antenna: conical Ø 40, 48, 75, 95

Materials: antenna: PTFE

housing: plastic PBT-FR / Aluminium/ AISI

flanges: AISI 316L / PTFE

Working temperature: -40…150°C

Storage temperature: -40 ÷ 80°C

Relative umidity: <95%

Pressure: -1 ÷ 16 bar

Resistance to vibrations: mechanical vibrations 10m/s2, 10÷150Hz

Frequency: 26 GHz

Angle emission lobe: Ø50 > 18°; Ø80…150 > 10°;

Interval of measure: ~1sec

Interval of updating: ~1sec

Resolution display: 1mm

Supply 2 wires version:

- Input voltage: 15÷36Vdc

- Absorption: max. 22.5mA

- Ripple allowed: <100Hz, Uss>1V;
100Hz÷100KHz, Uss<10mV

Supply 4 wires version:

- Standard input version voltage: 24Vdc ±10%; 230Vac ±10%

- Absorption: max. 4VA, 2W

Output signal: 2/4 wires 4-20 mA, HART

Resolution: 1,6μA

Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA

Time of integration: 0÷20s, programmable

Cables entry: 1x PG 13.5

Weight until ~6 kg (depending by flange Ø)
MakerBM TECHNOLOGIES
CategoryPulse Radar
Highlights 
Applications 
IndustryProcess Controls
KeywordsProcess Controls
Product Image
ModelCW56 BM SERIES WAVE COMPACT 26 GHZ- For Liquids & Solids
DescriptionCW56 for liquids and solids

Applications: Level measurement, suitable for highly corrosive media in defined
conditions of temperature or pressure.

Range: until 30 m

Accuracy: ± 3 mm

Process connection: G1½ “A flanges DN50, 80, 100, 150 AISI 316L

Antenna: Cones Ø 48, 78, 98, 98 Lengthen, 123

Materials: antenna: AISI 316L / PTFE / PP

housing: plastic PBT-FR / Aluminium / AISI

flanges: AISI 316L / PTFE / PP

Working temperature: -40 ÷400°C

Storage temperature: -40 ÷ 80°C

Relative umidity: <95%

Pressure of utilization: -1 ÷ 40 bar

Resistance to vibrations: mechanical vibrations10m/s2, 10÷150Hz

Frequency: 26 GHz

Angle emission lobe: Ø 40 >22°; Ø 48 >18°; Ø 75 >10° ; Ø 95 >8°

Interval of measure: ~1sec

Interval of updating: ~1sec

Resolution display: 1mm

Supply 2 wires version:

- Input voltages: 15÷36Vdc

- Absorption: 22.5mA

- Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV

Supply 4 wires version:

- Standard input voltages: 24Vdc ±10%; 230Vac ±10%

- Absorption: max. 4VA, 2W

Output signal: 2/4 wires 4-20 mA, HART
Resolution: 1,6μA

Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA

Integration time: 0÷20s, programmable

Cables entry: 1x PG 13.5

Weight: until ~5 kg (depending by flange Ø)
MakerBM TECHNOLOGIES
CategoryPulse Radar
Highlights 
ApplicationsLiquid and Solid Level
IndustryProcess Controls
Keywords 
Product Image
ModelCW55 BM SERIES WAVE COMPACT 26 GHZ- For Liquids
DescriptionCW55 for liquids

Applications:

Level measurement, suitable for highly corrosive media.

Range: until 10 m

Accuracy: ± 5 mm

Process connection: G1½ “A - NPT

Antenna: Pole

Materials: antenna: PVDF / PTFE

housing: plastic PBT-FR / Aluminium / AISI

flanges: AISI 316L

Working temperature: -40 ÷130°C

Storage temperature: -40 ÷ 80°C

Relative umidity: <95%

Pressure of utilization: -1 ÷ 3 bar

Resistance to vibrations: mechanical
vibrations10m/s2, 10÷150Hz

Frequency: 26 GHz

Angle emission lobe: 22°

Interval of measure: ~1sec

Interval of updating: ~1sec

Resolution display: 1mm

Supply 2 wires version:

- Input voltages: 15÷36Vdc

- Absorption: max. 22.5mA

- Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV

Supply 4 wires version:

- Standard input voltages: 24Vdc ±10%; 230Vac ±10%

- Absorption: max. 4VA, 2W

Output signal: 2/4 wires 4-20 mA, HART

Resolution: 1,6μA

Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA

Integration time: 0÷20s, programmable

Cables entry: 1x PG 13.5

Weight: ~2 kg
MakerBM TECHNOLOGIES
CategoryPulse Radar
HighlightsProcess Controls
ApplicationsLiquid Level
IndustryProcess Controls
Keywords 
Product Image
ModelCW54 BM SERIES WAVE COMPACT 6.3 GHZ- For Liquids & Solids
DescriptionCW54 for liquids and solids

Applications:

Storage tanks with hazardous working conditions.

Range: until70 m

Accuracy: 20 mm

Process connection: flanges SS 316L PN16
DN150, 200

Antenna: conical Ø 150, 200, 200(Lengthen) mm

Materials: antenna: SS 316L

housing: plastic PBT-FR / Aluminium/ AISI

flanges: AISI 316L

Working temperature: -40…200°C

Storage temperature: -40 ÷ 80°C

Relative umidity: <95%

Pressure: -1 ÷ 40 bar

Resistance to vibrations: mechanical vibrations 10m/s2, 10÷150Hz

Frequency: 6 GHz

Angle emission lobe: 24°

Interval of measure: ~1sec

Interval of updating: ~1sec

Resolution display: 1mm

Supply 2 wires version:

- Input voltage: 15÷36Vdc

- Absorption: max. 22.5mA

- Ripple allowed: <100Hz, Uss>1V;
100Hz÷100KHz, Uss<10mV

Supply 4 wires version:

- Standard input version voltage: 24Vdc ±10%; 230Vac ±10%

- Absorption: max. 4VA, 2W

Output signal: 2/4 wires 4-20 mA, HART
Resolution: 1,6μA

Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA

Time of integration: 0÷99s, programmable

Cables entry: 1x PG 13.5

Weight until ~10 kg (depending by flange Ø)
MakerBM TECHNOLOGIES
CategoryPulse Radar
Highlights 
Applicationsliquid and solid level
IndustryProcess Controls
KeywordsProcess Controls
Product Image
ModelCW53 BM SERIES WAVE COMPACT 6.3 GHZ- For Liquids & Solids
DescriptionCW53 for liquids and solids

Applications:

Storage tanks with hazardous working conditions.

Range: until30 m

Accuracy: 10 mm

Process connection: flanges AISI 316L SS PN16
DN50,80,100,150,200

Antenna: conicalsØ 50, 80, 100, 150, 200

Materials: antenna: SS 316L / PTFE

housing: plastic PBT-FR / Aluminium/ AISI

flanges: SS 316L

Working temperature: -40…200°C

Storage temperature: -40 ÷ 80°C

Relative umidity: <95%

Pressure: -1 ÷ 40 bar

Resistance to vibrations: mechanical
vibrations 10m/s2, 10÷150Hz

Frequency: 6 GHz

Angle emission lobe: 29°; 26°; 24°; 20° (depending by cones Ø)

Interval of measure: ~1sec

Interval of updating: ~1sec

Resolution display: 1mm

Supply 2 wires version:

- Input voltage: 15÷36Vdc

- Absorption: max. 22.5mA

- Ripple allowed: <100Hz, Uss>1V;
100Hz÷100KHz, Uss<10mV

Supply 4 wires version:

- Standard input version voltage: 24Vdc ±10%; 230Vac ±10%

- Absorption: max. 4VA, 2W

Output signal: 2/4 wires 4-20 mA, HART
Resolution: 1,6μA

Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA

Time of integration: 0÷99s, programmable

Cables entry: 1x PG 13.5

Weight until ~6 kg (depending by flange Ø)
MakerBM TECHNOLOGIES
CategoryPulse Radar
HighlightsProcess Controls
ApplicationsLiquid Level, solid level
IndustryProcess Controls
KeywordsPulse Radar
Product Image
ModelCW52 BM SERIES WAVE COMPACT 6.3 GHZ- For Liquids
DescriptionCW52 for liquids

Applications: Level measurement, suitable for highly corrosive media in defined
conditions of temperature or pressure.

Range: until 30 m

Accuracy: 10 mm

Process connection: Protected flanges SS 316L PN16
DN 50, 100, 150, 200, 250, 300 PTFE

Antenna: Rod

Materials: antenna: PTFE

housing: plastic PBT-FR / Aluminium / AISI

flanges: SS 316L

Working temperature: -40 ÷150°C

Storage temperature: -40 ÷ 80°C

Relative umidity: <95%

Pressure of utilization: -1 ÷ 16 bar

Resistance to vibrations: mechanical vibrations10m/s2, 10÷150Hz

Frequency: 6 GHz

Angle emission lobe: 24°

Interval of measure: ~1sec

Interval of updating: ~1sec

Resolution display: 1mm

Supply 2 wires version:

- Input voltages: 15÷36Vdc

- Absorption: 22.5mA

- Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV

Supply 4 wires version:

- Standard input voltages: 24Vdc ±10%; 230Vac ±10%

- Absorption: max. 4VA, 2W

Output signal: 2/4 wires 4-20 mA, HART
Resolution: 1,6μA

Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA

Integration time: 0÷99s, programmable
Cables entry: 1x PG 13.5

Weight: until ~5 kg (depending by flange Ø)
MakerBM TECHNOLOGIES
CategoryPulse Radar
Highlights 
ApplicationsLiquid Level
IndustryProcess Controls
Keywords 
Product Image
ModelCW51 BM SERIES WAVE COMPACT 6.3 GHZ- For Liquids
DescriptionCW51 for liquids

Applications:

Level measurement, Suitable for highly corrosive media.

Range: until 30 m

Accuracy: ± 10 mm

Process connection: G1½ “A - NPT

Antenna: Rod

Materials: antenna: PP / PTFE

housing: plastic PBT-FR / Aluminium / Stainless Steel 316L

flanges: AISI 316L

Working temperature: -40 ÷120°C

Storage temperature: -40 ÷ 80°C

Relative umidity: <95%

Pressure of utilization: -1 ÷ 3 bar

Resistance to vibrations: mechanical vibrations 10m/s2, 10÷150Hz

Frequency: 6 GHz

Angle emission lobe: 24°

Interval of measure: ~1sec

Interval of updating: ~1sec

Resolution display: 1mm

Supply 2 wires version:

- Input voltages: 15÷36Vdc

- Absorption: max. 22.5mA

- Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV

Supply 4 wires version:

- Standard input voltages: 24Vdc ±10%; 230Vac ±10%

- Absorption: max. 4VA, 2W

Output signal: 2/4 wires 4-20 mA, HART
Resolution: 1,6μA

Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA

Integration time: 0÷99s, programmable
Cables entry: 1x PG 13.5

Weight: ~2 kg
MakerBM TECHNOLOGIES
CategoryPulse Radar
Highlights 
ApplicationsLiquid Level
IndustryProcess Control
Keywords 
Product Image
ModelLU-C2100 Blue (LU-C3000 Color) LCD program PID Control
Description1.Brief Introduction

LU-C2100 blue (LU-C3000 color) series recorders may be 1 to 8 channels program PID control and the program control curve may reach 200 segments.


2. technical parameters

◆ Display windows : 320×240 high resolution chart blue-white LCD

◆ Input accuracy: ± (0.2%F.S+1) digit

◆input type: Standard voltage 0-5V, 1-5V

standard current 0-10mA, 4-20mA

T.C: K, S, B, T, E, J, Wre325, N

RTD: Pt100, Cu50, Cu100

specially input: R, WRe526, mV signal, other

◆output types: Switch output: Relay contact output (resistance 250VAC/0.8A or 250VAC/3A)

linear current output: 0-10mA, 4-20mA, 0-20mA (software free set)

linear voltage output: 0-5V, 1-5V, 0-10V (indicates when ordering)

silicon-controlled zero-crossing trigger
the SSR trigger (12V/50mA)
DC12V/50mA
DC24V/50mA
DC5V/50mA

the transform output: 4-20mA (the load <650Ω)、1-5V
0-10mA(the load <1000Ω)、0-5V

Communication connection: RS232 or RS485
storage medium: U disk/256M, U disk/512M

◆5 to 200 segments of control curves

◆Record date: 8 pens

without U disk, 5.69 days /pen (1 sceond interval) ~3.7 years /pen (4 minutes interval)
U disk/256M, 256×[5.69 days /pen (1 sceond interval) ~3.7 years /pen (4 minutes interval)]

◆Storage time: T=storage capacity/ the sum of the reciprocal of every open channel’s record interval; when storage data is temple, the storage capacity also the total storage is 976×504.

For example: when the storage data is temple, the open channels are 1, 3, 5, 7, the record interval of every channel is 1second, 5seconds, 10 seconds, 20seconds, then
T= 976×504/(1/1+1/5+1/10+1/20)=364373 seconds=101.21 hours=4.22 days

◆cut off protection time: the data can be stored forever when the electricity is cut off for it adopts FLASH MEMORY, it can run accurately when cut off if hard clocks is equipped.

◆Power source: Switch power supply 85VAC-264VAC, 50Hz±1Hz, power consumption 12W

◆Ambient temperature: 0-45 ℃

◆ambient humidity: 0-85%RH
MakerAnthone
CategoryPaperless Electronic Recorders
Highlights 
ApplicationsProcess Controls
IndustryRecorder
KeywordsAutomation
Product Image