12 |AEROQUAL |
Series 905 Transmitter/Controller
The Series 905, with temperature & relative humidity sensors, has multiple output capability and can be included into a network of monitors.
Power (user supplied): Regulated 12 VDC, 800 mA
Analog output: 4-20 mA (opto-isolated), 10-30 V
External signal type :Transistor output
External signals : 4
External signal functions: Low Alarm, High Alarm, Control & Diagnostics
Inputs: Standby toggle
Communication: RS485
Jumpers: J1, J2, J3 termination resistors
Connectors: Screw
ID :1 (Default) - User configurable from 1 - 255
Alarm set points (2): User configurable
Control set point :User configurable
RS485 protocol: Aeroqual proprietary product
Removable / replaceable sensor head: Yes
Enclosure rating: IP20 & NEMA 1 equivalent
Enclosure size (with base unit)
64 H x 130 Ø (mm); 2½ H x 5? Ø (in)
Mounting: Screw fixture
Weight: < 200 g; < 7 oz
Approvals
Part 15 of the FCC Rules, EN 50082-1: 1997, EN 50081-1: 1992
|
Series 905 Transmitter/Controller
|
Gas Sensitive Semiconductor|Environment |
|
11 |AEROQUAL |
Series 900 Transmitter/Controller
The Series 900 has multiple output capability and can be included into a network of monitors.
Power (user supplied):24 VDC, (range 16 - 28 VDC), 500 mA
I/O connectors (power, control signal):
Eight pole M12 female panel mount connector and eight pole male cord connector
Setting control and alarms:dip switches
External signal for control & switching: Volt free (150 mA max, 24VDC max, resistive)
External signals: 2
External signal functions: Alarm (Low Alarm & High Alarm) or Control
Removable / replaceable sensor head: Yes
LED status indicator: Low, high, within control band, diagnostics
Enclosure rating: IP20 & NEMA 1 equivalent
Enclosure size (with base unit: 180W x 110H x 90D (mm)
Enclosure casing: Fibre reinforced plastic
Weight: < 850 g; < 30 oz
Approvals:Part 15 of the FCC Rules
EN 55022: 1998
EN 61000-6-1: 2001
|
Series 900 Transmitter/Controller
|
Gas Sensitive Semiconductor|Environment |
|
10 |AEROQUAL |
Series 130 Controller
The Series 130 ozone controller is designed to be operated as part of an ozone generator control circuit or alarm system.
Power (user supplied): 24 VDC, (range 16 - 28 VDC), 500 mA
I/O connectors (power, control signal):
Eight pole M12 female panel mount connector and eight pole male cord connector
Setting control and alarms: dip switches
External signal for control & switching: Volt free (150 mA max, 24VDC max, resistive)
External signals : 2
External signal functions: Alarm (Low Alarm & High Alarm) or Control
Removable / replaceable sensor head:
Yes
LED status indicator: Low, high, within control band, diagnostics
Enclosure rating: IP20 & NEMA 1 equivalent
Enclosure size (with base unit: 180W x 110H x 90D (mm)
Enclosure casing:Fibre reinforced plastic
Weight: < 850 g; < 30 oz
Approvals:Part 15 of the FCC Rules
EN 55022: 1998
EN 61000-6-1: 2001
|
Series 130 Controller
|
Gas Sensitive Semiconductor|Environment |
|
9 |AEROQUAL |
Series 100 Controller
The Series 100 ozone controller is designed to be operated as part of an ozone generator control circuit or alarm system.
Power (user supplied): Regulated 12 VDC, 400 mA
Unit interface (power in, control signal out): RJ45 connector
Setting control and alarms: dip switches
External signal for control & switching :Volt free (150 mA max, 24VDC max, resistive)
External signals: 2
External signal functions: Alarm (Low Alarm & High Alarm) or Control
Removable/replaceable sensor head: Yes
LED status indicator: Low, high, within control band, diagnostics
Enclosure rating: IP20 & NEMA 1 equivalent
Enclosure size (with base unit):64 H x 130 Ø (mm); 2½ H x 5? Ø (in)
Weight: < 200 g; < 7 oz
Approvals:
Part 15 of the FCC Rules
EN 55022: 1998
EN 61000-6-1: 2001
3-Colour LED:
Below Low Limit
Between Low and High Limits
Above High Limit
|
Series 100 Controller
|
Gas Sensitive Semiconductor|Environment |
|
8 |AEROQUAL |
SM 70
The SM 70 monitor/controller (with display) is designed for basic gas monitoring where simple control outputs (0-5V & a relay) are required.
Power supply
12 VDC, 800 mA plug-in AC power adaptor
Removable / replaceable sensor module
Micro-match connector
LCD display: Gas concentration in ppm
Audible alarm: Optional
Alarm set point: User adjustable
Operational mode: Continuous
Permanently fixable: Screw fix
Enclosure rating: IP 66, EN 60529
Enclosure size: 130W x 94H x 57D (mm); 5 1/8 W x 3¾H x 2¼ D (in)
Enclosure casing: Flame resistant thermoplast PS
Weight: 285 g; 10 oz (excludes AC power adaptor
|
SM 70
|
Gas Sensitive Semiconductor|Environment |
|