... | Previous | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | Next
17 |AEROQUAL |
Series 945 Transmitter/Controller
The Series 945 is supplied in an FRP enclosure, has multiple output capability and can be included into a realtime network of monitors.
Typical application
Short distance remote monitoring for:-
• Low Oxygen environments (3-5% O 2 )
• Indoor air quality - duct sampling
• Filtered air sampling
Power (user supplied): 24VDC, 500mA (range 22-26 VDC)
Analogue output: 4-20 mA (opto-isolated), 12-24 V
External signal type: Transistor Output
External signals: 4
External signal functions:
Low Alarm, High Alarm, Control & Diagnostics
LED Display: (Optional)
Inputs : Standby toggle
Communication: RS485
Jumpers: J1, J2, J3 termination resistors
Connectors: Screw
ID: 1 (Default)
User configurable from 1 - 255
Alarm set points (2): User configurable
Control set point: User configurable
RS485 protocol: Aeroqual proprietary product
Removable / replaceable sensor head:
Yes
Sampling Pump:12VDC, long life, brushless, diaphram pump
Enclosure rating: IP41 & NEMA 2 equivalent
Enclosure size: 230W x 140H x 95D (mm); 9"W x 5½"H x 3¾"D (in)
Enclosure casing: Fibre reinforced polycarbonate
Weight: < 1100 g; < 1 lb 3 oz
Approvals: Part 15 of the FCC Rules
EN 50082-1: 1997
EN 50081-1: 1992
|
Series 945 Transmitter/Controller
|
Gas Sensitive Semiconductor|Environment |
|
16 |AEROQUAL |
Series 940 Transmitter/Controller
The Series 940 is supplied in an FRP enclosure, has multiple output capability and can be included into a realtime network of monitors.
Typical application : Short distance remote monitoring for:-
• Low Oxygen environments (3-5% O 2 )
• Indoor air quality - duct sampling
• Filtered air sampling
Power (user supplied):24VDC, 500mA (range 22-26 VDC)
Analogue output: 4-20 mA (opto-isolated), 12-24 V
External signal type: Transistor Output
External signals: 4
External signal functions: LED Display
Low Alarm, High Alarm, Control & Diagnostics (Optional)
Inputs: Standby toggle
Communication: RS485
Jumpers:J1, J2, J3 termination resistors
Connectors: Screw
ID: 1 (Default) User configurable from 1 - 255
Alarm set points (2):User configurable
Control set point: User configurable
RS485 protocol: Aeroqual proprietary product
Removable/replaceable sensor head: Yes
Sampling Pump:12VDC, long life, brushless, diaphram pump
Enclosure rating: IP41 & NEMA 2 equivalent
Enclosure size: 230W x 140H x 95D (mm); 9"W x 5½"H x 3¾"D (in)
Enclosure casing:Fibre reinforced polycarbonate
Weight: < 1100 g; < 1 lb 3 oz
Approvals: Part 15 of the FCC Rules
EN 50082-1: 1997
EN 50081-1: 1992
|
Series 940 Transmitter/Controller
|
Gas Sensitive Semiconductor|Environment |
|
15 |AEROQUAL |
Series 935 Transmitter/Controller
The Series 935, with temperature sensor, is supplied in an FRP enclosure, has multiple output capability and can be included into a realtime network of monitors.
Power (user supplied): 24VDC, 500mA (range 22-26 VDC)
Analogue output: 4-20 mA (opto-isolated), 12-24 V
External signal type:Transistor Output
External signals: 4
External signal functions:
LED Display
Low Alarm, High Alarm, Control & Diagnostics (Optional)
Inputs: Standby toggle
Communication : RS485
Jumpers: J1, J2, J3 termination resistors
Connectors: Screw
ID: 1 (Default) User configurable from 1 - 255
Alarm set points (2):User configurable
Control set point:User configurable
RS485 protocol: Aeroqual proprietary product
Removable / replaceable sensor head: Yes
Enclosure rating:IP41 & NEMA 2 equivalent
Enclosure size: 180W x 110H x 90D (mm); 7?W x 4¾H x 3½D (in)
Enclosure casing: Fibre reinforced polycarbonate
Weight: < 850 g; < 30 oz
Approvals: Part 15 of the FCC Rules
EN 50082-1: 1997
EN 50081-1: 1992
|
Series 935 Transmitter/Controller
|
Gas Sensitive Semiconductor|Environment |
|
14 |AEROQUAL |
Advice FCnote
|
AEROQUAL
|
Gas Sensitive Semiconductor| |
|
13 |AEROQUAL |
Series 930 Transmitter/Controller
The Series 930 is supplied in an FRP enclosure, has multiple output capability
and can be included into a realtime network of monitors.
Power (user supplied): 24VDC, 500mA (range 22-26 VDC)
Analogue output: 4-20 mA (opto-isolated), 12-24 V
External signal type : Transistor Output
External signals : 4
External signal functions:LED Display
Low Alarm, High Alarm, Control & Diagnostics (Optional)
Inputs: Standby toggle
Communication: RS485
Jumpers:J1, J2, J3 termination resistors
Connectors:Screw
ID: 1 (Default) User configurable from 1 - 255
Alarm set points (2):User configurable
Control set point:User configurable
RS485 protocol: Aeroqual proprietary product
Removable/replaceable sensor head: Yes
Enclosure rating:IP41 & NEMA 2 equivalent
Enclosure size: 180W x 110H x 90D (mm); 7?W x 4¾H x 3½D (in)
Enclosure casing: Fibre reinforced polycarbonate
Weight: < 850 g; < 30 oz
Approvals: Part 15 of the FCC Rules
EN 50082-1: 1997
EN 50081-1: 1992
|
Series 930 Transmitter/Controller
|
Gas Sensitive Semiconductor|Environment |
|