Back to Site Control Panel | Show All | Search | Previous | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | Next | ...
| 120 |BM TECHNOLOGIES |
CW51 for liquids
Applications:
Level measurement, Suitable for highly corrosive media.
Range: until 30 m
Accuracy: ± 10 mm
Process connection: G1½ “A - NPT
Antenna: Rod
Materials: antenna: PP / PTFE
housing: plastic PBT-FR / Aluminium / Stainless Steel 316L
flanges: AISI 316L
Working temperature: -40 ÷120°C
Storage temperature: -40 ÷ 80°C
Relative umidity: <95%
Pressure of utilization: -1 ÷ 3 bar
Resistance to vibrations: mechanical vibrations 10m/s2, 10÷150Hz
Frequency: 6 GHz
Angle emission lobe: 24°
Interval of measure: ~1sec
Interval of updating: ~1sec
Resolution display: 1mm
Supply 2 wires version:
- Input voltages: 15÷36Vdc
- Absorption: max. 22.5mA
- Ripple allowed: <100Hz, Uss>1V; 100Hz÷100KHz, Uss<10mV
Supply 4 wires version:
- Standard input voltages: 24Vdc ±10%; 230Vac ±10%
- Absorption: max. 4VA, 2W
Output signal: 2/4 wires 4-20 mA, HART
Resolution: 1,6μA
Fixed signal for anomaly: 20.5mA; 22mA; 3.8mA
Integration time: 0÷99s, programmable
Cables entry: 1x PG 13.5
Weight: ~2 kg

|
|
CW51 BM SERIES WAVE COMPACT 6.3 GHZ- For Liquids
|
| Pulse Radar|Process Control |
|
| 119 |Anthone |
1.Brief Introduction
LU-C2100 blue (LU-C3000 color) series recorders may be 1 to 8 channels program PID control and the program control curve may reach 200 segments.
2. technical parameters
◆ Display windows : 320×240 high resolution chart blue-white LCD
◆ Input accuracy: ± (0.2%F.S+1) digit
◆input type: Standard voltage 0-5V, 1-5V
standard current 0-10mA, 4-20mA
T.C: K, S, B, T, E, J, Wre325, N
RTD: Pt100, Cu50, Cu100
specially input: R, WRe526, mV signal, other
◆output types: Switch output: Relay contact output (resistance 250VAC/0.8A or 250VAC/3A)
linear current output: 0-10mA, 4-20mA, 0-20mA (software free set)
linear voltage output: 0-5V, 1-5V, 0-10V (indicates when ordering)
silicon-controlled zero-crossing trigger
the SSR trigger (12V/50mA)
DC12V/50mA
DC24V/50mA
DC5V/50mA
the transform output: 4-20mA (the load <650Ω)、1-5V
0-10mA(the load <1000Ω)、0-5V
Communication connection: RS232 or RS485
storage medium: U disk/256M, U disk/512M
◆5 to 200 segments of control curves
◆Record date: 8 pens
without U disk, 5.69 days /pen (1 sceond interval) ~3.7 years /pen (4 minutes interval)
U disk/256M, 256×[5.69 days /pen (1 sceond interval) ~3.7 years /pen (4 minutes interval)]
◆Storage time: T=storage capacity/ the sum of the reciprocal of every open channel’s record interval; when storage data is temple, the storage capacity also the total storage is 976×504.
For example: when the storage data is temple, the open channels are 1, 3, 5, 7, the record interval of every channel is 1second, 5seconds, 10 seconds, 20seconds, then
T= 976×504/(1/1+1/5+1/10+1/20)=364373 seconds=101.21 hours=4.22 days
◆cut off protection time: the data can be stored forever when the electricity is cut off for it adopts FLASH MEMORY, it can run accurately when cut off if hard clocks is equipped.
◆Power source: Switch power supply 85VAC-264VAC, 50Hz±1Hz, power consumption 12W
◆Ambient temperature: 0-45 ℃
◆ambient humidity: 0-85%RH

|
|
LU-C2100 Blue (LU-C3000 Color) LCD program PID Control
|
| Paperless Electronic Recorders|Recorder |
|
| 118 |Anthone |
1. Brief Introduction
The LU-C5000 may be 1 to 32 channels program PID control, the program control curve may reach 200 segments.
2. The main technical parameters
◆ Display: 10.4 inch TFT active color LCD, resolution 640×480, high light , none view angle.
◆ Input accuracy: ± (0.2%F.S+1) digit
◆input type: Standard voltage 0-5V, 1-5V
standard current 0-10mA, 4-20mA
T.C: K, S, B, T, E, J, Wre325, N
RTD: Pt100, Cu50
Special input: R, Wre526, mV signal, other
◆ output types: Switch output: Relay contact output (resistance 250VAC/0.8A or 250VAC/3A)
linear current output: 0-10mA, 4-20mA, 0-20mA (software free set)
linear voltage output: 0-5V, 1-5V, 0-10V (indicates when ordering)
silicon-controlled zero-crossing trigger
the SSR trigger (12V/50mA)
DC12V/50mA
DC24V/50mA
DC5V/50mA
transform output: 4-20mA (the load <650Ω)、1-5V
0-10mA(the load <1000Ω)、0-5V
Communication connection: RS232 or RS485
storage medium: U disk/256M, U disk/512M
◆ Record time: adopts 256M electron hard disk
Record interval: 1, 2, 5, 10, 15, 30, 60, 120, 240, 300seconds for set
Record data: 32 pens,
Latest 21 days/32 pens (1 second interval) ~ 6300 days/ 32 pens (5 minutes interval)
◆T.C cold-junction compensate error: ±1℃
◆cut off protection time: the data can be stored forever when the electricity is cut off for it adopts FLASH MEMORY, it can run accurately when cut off if hard clocks is equipped.
◆Power source: Switch power supply 85VAC-264VAC, 50Hz±5%
◆Ambient temperature: 0-45 ℃
◆ambient humidity: 0-85%RH

|
|
LU-C5000 active color LCD program PID Control paperless recorders
|
| Paperless Electronic Recorders|Automation |
|
| 117 |Anthone |
1. Brief Introduction
LU-R5000 series active color LCD Recorders may be 1 to 64 channels input, have outputs of status control, alarm, sensors power supply etc.
2. The main technical parameters
◆ Display: 10.4 inch TFT active color LCD, resolution 640×480, high light , none view angle.
◆ Input accuracy: ± (0.2%F.S+1) digit
◆input type: Standard voltage 0-5V, 1-5V
standard current 0-10mA, 4-20mA
T.C: K, S, B, T, E, J, Wre325, N
RTD: Pt100, Cu50
Special input: R, Wre526, mV signal, other
◆output types: Switch output: Relay contact output (resistance 250VAC/0.8A or 250VAC/3A)
the SSR trigger (12V/50mA)
DC12V/50mA
DC24V/50mA
DC5V/50mA
transform output: 4-20mA (the load <650Ω)、1-5V
0-10mA(the load <1000Ω)、0-5V
Communication connection: RS232 or RS485
storage medium: U disk/256M, U disk/512M
◆ Record time: adopts 256M electron hard disk
Record interval: 1, 2, 5, 10, 15, 30, 60, 120, 240, 300seconds for set
Record data: 64 pens,
latest 10.5 days/64 pens (1 second interval) ~ 3150 days/ 64 pens (5 minutes interval)
◆T.C cold-junction compensate error: ±1℃
◆cut off protection time: the data can be stored forever when the electricity is cut off for it adopts FLASH MEMORY, it can run accurately when cut off if hard clocks is equipped.
◆Power source: Switch power supply 85VAC-264VAC, 50Hz±5%
◆Ambient temperature: 0-45 ℃
◆ambient humidity: 0-85%RH

|
|
LU-R5000 TFT LCD Paperless Recorder
|
| Paperless Electronic Recorders|Automation |
|
| 116 |Anthone |
1. Brief Introduction
LU-C1000 series recorders may be 1 to 3 channels programmable PID control and the program control curve may reach 100 segments.
2. Technical parameter
◆ Outline dimension: 160*80cm
◆ Input accuracy: ± (0.2%F.S+1) digit
◆ Input type:
standard voltage 0-5V, 1-5V
standard current 0-10mA, 4-20mA
T.C: K, S, B, T, E, J, Wre325, N
RTD: Pt100, Cu50, Cu100
specially input: R, WRe526, the mV signal, other (indicated when ordering)
◆ Output type:
Switch output: Relay (resistance 250VAC/0.8A or 250VAC/3A)
Linear current output: 0-10mA, 4-20mA, 0-20mA (software sets freely)
Linear voltage output: 0-5V, 1-5V, 0-10V (indicated when ordering)
Silicon-controlled zero-crossing trigger;SSR trigger (12V/50mA)
Sensor power supply: DC12V/50mA
DC24V/50mA; DC5V/50mA
transform output: 4-20mA (load <650Ω), 1-5V ; 0-10mA (load <1000Ω), 0-5V
communication connection: RS232 or RS485
storage medium: U disk/512M, U disk/1G, U disk/2G,
◆ 5 to 100 segments of control curves
◆ Power off protection time: the data can be stored forever when the power is cut off because it adopts FLASH MEMORY,
it can run accurately when power off because hard clocks is equipped.
◆ Power: Switch power supply 85VAC-264VAC, 50Hz±1Hz, power consumption is 12W;
◆ Ambient temperature: 0-45 ℃
◆ Ambient humidity: 0-85%RH

|
|
LU-C1000 Programmable PID Paperless Recorder
|
| Paperless Electronic Recorders|Automation |
|
| 115 |Anthone |
1. Brief Introduction
LU-R1000 paperless recorders may be 1 to 4 channels input, have outputs of status control, alarm, sensors power supply etc
◆ Outline demesion: 160*80cm
◆ Input accuracy: ± (0.2%F.S+1)digit
◆ Input type:
standard voltage 0-5V, 1-5V standard current 0-10mA, 4-20mA
T.C: K, S, B, T, E, J, Wre325, N
RTD: Pt100, Cu50, Cu100 specially input: R, WRe526, the mV signal, other(indicated when ordering)
◆ Output type:
Switch output: Relay (resistance 250VAC/0.8A or 250VAC/3A)
SSR trigger (12V/50mA)
sensor power supply:DC12V/50mA ;DC24V/50mA;DC5V/50mA
transform output: 4-20mA (load <650Ω), 1-5V;0-10mA (load <1000Ω),0-5V
communication connection: RS232 or RS485
storage medium: U disk/512M, U disk/1G, U disk/2G.
◆ Power off protection time: the data can be stored forever when the power is cut off because it adopts FLASH MEMORY,
it can run accurately when power off because hard clocks is equipped.
◆ Power: Switch power supply 85VAC-264VAC, 50Hz±1Hz, power consumption is 12W;
◆ Ambient temperature: 0-45 ℃
◆ Ambient humidity: 0-85%RH

|
|
LU-R1000 paperless recorder
|
| Paperless Electronic Recorders|Automation |
|